Complexometric Determination of Water Hardness
Complexometric Determination of Water Hardness Abstract: Create a standardized EDTA solution for use as a titration solution to determine the hardness of water from a single random sample. Introduction: Using a calibrated EDTA solution to determine water hardness from a random sample. Essentially the Na2EDTA solution reacts one to one with the mineral content of a sample of tap water and by use of a standardized solution a ppm estimation can be obtained for the hardness of water.Current knowledge in this area is well understood and procedures used follow generally accepted guidelines. Method: First the calibration was completed using an approximately . 7340g Na2EDTA/500mL solution. A 1. 000g/L calcium ion solution was used as the primary standard with approximately 3mL of ammonium chloride as a buffer and Erichrome Black T as the indicator solution. Three titrations were performed to ensure accuracy of the molarity of the Na2EDTA solution. The 1. 000g/L calcium ion solution had to be converted to M so 1g/L/100. g=. 009990M calcium ion solution. Titration 1: 10. 00mL CaCO3; . 00999MCaCO3X. 0100L= . 0000999mol CaCO3 . 0000999mol EDTA/. 002507L = . 00398M Na2EDTA Titration 2: 10. 00mL CaCO3; . 00999MCaCO3X. 0100L= . 0000999mol CaCO3 . 0000999mol EDTA/. 02339L = . 004271M Na2EDTA Titration 3: 9. 95mL CaCO3; . 00999MCaCO3X. 0100L= . 0000994mol CaCO3 . 0000994mol EDTA/. 02367L = . 004196M Na2EDTA Since the first titration is so far out from the other two it was thrown out giving an average result of . 04233M Na2EDTA Sample B was used in this experiment with at 25mL and three titrations were performed to ensure accuracy with the same buffer solution (appx 3mL ammonium chloride @ pH10). A magnetic stirrer and standard burette were used in the procedure with a read accuracy to . 01mL. Eriochrome Black T was the indicator solution. Results: Titration 1: 12. 52mL Na2EDTA; . 00423M Na2EDTA x . 01252L = . 0000530 mol . 0000530mol/. 02496L = . 00212M hardness Titration 2: 12 . 19mL Na2EDTA; . 00423M Na2EDTA x . 01219L = . 0000516 mol . 0000516mol/. 2499L = . 00206M hardness Titration 1: 12. 23mL Na2EDTA; . 00423M Na2EDTA x . 01223L = . 0000517 mol .0000517mol/. 02505L = . 00206M hardness (. 00212M+. 00206M+. 00206M)/3 = . 00208M Discussion: The results are very consistent however the website for checking the data is no longer valid. Provided that the titration solution was calibrated properly the results from the experiment to determine the hardness of water should be accurate with a margin of consistency between samples vs. average hardness @ 1. 89% at most for any of the three samples.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.